How the rankings work
Start with the heating and cooling loads for the room. Use those to choose a size, then choose what to rank. The lowest equipment and electricity cost comes first in the default view. A small system can be inexpensive and still leave the room cold. How to match a heat pump to the room’s load
Places are assigned within your filtered results and continue across pages. Equal displayed values share a place, so two systems tied for second are followed by fourth place. Dollars are compared to the cent and energy use to a tenth of a kWh. A dash means a measurement is missing or you are browsing in catalog or capacity order.
Equipment and ten years of electricity
Add the equipment price to the cost of running every pair under the same loads. The starting example delivers 10 million Btu of heat and removes 10 million Btu of heat per year, at $0.18/kWh. Change the loads or the rate to match your project. These are example inputs. An energy model for the room can supply better ones.
- Electricity per million Btu
- Cooling = 1,000 ÷ SEER2. Heating = 1,000 ÷ HSPF2 (Region IV). Both results are in kWh.
- Annual kWh
- Cooling load × cooling kWh per million Btu + heating load × heating kWh per million Btu. Enter each annual load in millions of Btu.
- Ten-year estimate in dollars
- Equipment price + 10 × annual kWh × electricity rate.
The scenario holds the equipment, annual loads and electricity rate constant over ten years. Installation, maintenance, taxes, financing, replacement equipment and separate backup heat are outside it. Site conditions and controls affect the actual electricity bill. ENERGY STAR rating definitions · U.S. Department of Energy cost-comparison method
What a dollar buys in cold weather
Divide the equipment price by heating output at 5°F in thousands of Btu/h. A lower figure buys more output per dollar. Compare the output in Btu/h with the room’s heat loss at that same temperature. Each model sheet identifies an exact EPA match or a model-family match.
To compare electricity use during a cold spell, divide 1,000,000 by (3,412.142 × COP at 5°F). This gives the kWh required to deliver a million Btu at that test point. The seasonal heating row uses HSPF2 across a range of outdoor temperatures.
Light loads and bedroom noise
Look at the lowest steady heating output at 47°F and the lowest steady cooling output at 95°F. When the room needs less than the minimum, the system may cycle on and off. Comparing absolute Btu/h is useful even when two units have the same advertised size. The cooling sound range shows what happens between the quietest and highest published fan settings. Smaller dB(A) values indicate lower measured sound pressure. Fan speed and the room itself affect what you hear. Reading an indoor fan sound rating
Two 12,000 Btu/h systems
Both pairs below have the same rated cooling output. One is cheaper to buy and delivers more heat at 5°F. The other can run at a lower cooling output when a room needs less cooling. Dollar estimates use the starting loads and rate above.
| Measurement | ACiQ Platinum | Mitsubishi GX |
|---|---|---|
| Equipment price | $1,649.99 | $2,676.16 |
| Equipment and ten years of electricity | $4,072.94 | $5,061.53 |
| Heat delivered at 5°F | 11,500 Btu/h | 10,100 Btu/h |
| Equipment price per 1,000 Btu/h at 5°F | $143.48 | $264.97 |
| Minimum heating at 47°F | 3,800 Btu/h | 1,500 Btu/h |
| Minimum cooling at 95°F | 3,800 Btu/h | 1,300 Btu/h |
Who writes the guides and how the site is funded
MiniSplit Scout publishes this U.S. equipment directory and its buying guides. For each matched pair, the model sheet lists the technical documents behind the numbers and the retailers behind the equipment price. Sound and output figures come from the published tests under the conditions shown.
The installation phone line may earn the site a referral fee when a homeowner calls. Equipment rankings use the selected measurement, the price sources listed on the model sheet and, for running costs, the electricity assumptions you choose.
What’s in this edition
50 single-zone wall-mounted systems documented for the U.S. market, across 5 brands. We selected several sizes within each product line. Models are grouped by rated cooling capacity in the catalog. The exact rating is shown on each system page.
Manufacturer submittals and engineering manuals supply most model-specific ratings. Some series use a manufacturer document hosted by a distributor, or a distributor sheet checked against the engineering manual. Product pages link to the material used.
For 21 pairs, both model numbers matched a U.S. ENERGY STAR record exactly. Another 21 matched model patterns published by EPA, where trailing asterisks cover permitted variants. For the remaining 8, we found no matching row in the records checked. Their published manufacturer ratings remain visible. The catalog was checked on .
Retail prices and size-class benchmarks
We check U.S. retailer listings for the exact indoor and outdoor units. If a seller lists the units separately, we add its two prices. Each seller counts once. With two or more sellers we show their arithmetic mean, and with one we show the seller’s price. Tax, shipping and installation are separate. Each model sheet links to the listings and shows the date checked.
Earlier price and efficiency score
The model sheets also carry a weighted benchmark from the original catalog. The comparison group is the nearest rated cooling size of 6,000, 9,000, 12,000, 15,000, 18,000 or 24,000 Btu/h. The price reference is the median of the pairs’ equipment prices. Each pair gets one vote. We find the median of each efficiency rating in the same size class.
The score adds 40 × (median price ÷ pair price), 25 × (SEER2 ÷ median SEER2), 25 × (HSPF2 ÷ median HSPF2) and 10 × (EER2 ÷ median EER2). At all four medians the score is 100. For the efficiency-only benchmark, add the last three terms and divide by 0.60.
One retailer’s price makes this score provisional. Computing it requires at least two priced pairs in the class and all three efficiency ratings for the pair.
Additional reference calculations
We use fixed editorial references of 18 SEER2, 12 EER2, 9 HSPF2 and 30 dB(A). The first four formulas compare electricity use for the same useful load. Multiply each ratio by 100 to display a percentage. The sound margin is measured in decibels. A negative percentage means the system needs more electricity in that scenario. Rates, local weather and hours of operation determine the dollar amount on a bill.
Cooling electricity over a season
50 of 50 pairs1 − 18 ÷ SEER2For the same amount of heat removed, compare electricity use with a system rated 18 SEER2.
Electricity at the cooling test point
50 of 50 pairs1 − 12 ÷ EER2Compare input power for the same cooling output at the EER2 test point. The reference is 12 EER2.
Heating electricity over a season
50 of 50 pairs1 − 9 ÷ HSPF2Compare seasonal electricity use for the same heat delivered. The reference is 9 HSPF2 in climate Region IV.
Electricity across both seasons
50 of 50 pairs1 − [w ÷ SEER2 + (1 − w) ÷ HSPF2] ÷ [w ÷ 18 + (1 − w) ÷ 9]Here w is the share of useful heating and cooling load devoted to cooling. The catalog uses 0.5, giving equal weight to heat removed and heat delivered.
Heat retained at 5°F
42 of 50 pairsHeating output at 5°F ÷ rated heating output at 47°FBoth values come from the same ENERGY STAR record. A system that delivers more than its 47°F nominal rating at 5°F can show a result above 100%.
Cooling modulation depth
34 of 50 pairs1 − minimum cooling at 95°F ÷ rated cooling at 95°FThe percentage shows how far the system can turn down from rated cooling capacity at the same 95°F outdoor test point.
Indoor sound margin
45 of 50 pairs30 dB(A) − minimum indoor cooling sound pressureA positive value is the number of decibels below the chosen reference at the quietest published cooling setting. It says nothing about fan speed on a particular night.
Checking heating capacity retention
The Mitsubishi GX12 pair supplies 10,100 Btu/h at 5°F and has a 14,400 Btu/h heating rating at 47°F in its EPA record. Divide the first figure by the second to get 70.1%. The ACiQ Platinum 12k pair returns 95.8% using the same method. Their rated cooling capacities both happen to be 12,000 Btu/h.
When two sources differ
We cross-checked nominal cooling capacity, SEER2, EER2, HSPF2 and rated heat at 47°F where both records give comparable conditions. These are the differences we found. Cooling and seasonal comparisons use the manufacturer figure. The 5°F retention calculation always uses the two EPA figures together.
| Indoor unit | Rating | Manufacturer | EPA |
|---|---|---|---|
| LIV18HP230V1R32AH | EER2 | 12.35 | 12 |
| LIV18HP230V1R32AH | Rated heat at 47°F (Btu/h) | 19,100 | 17,000 |
| CS-XZ12AKUAW | EER2 | 14.35 | 15 |
| CS-XZ12AKUAW | Rated cooling capacity (Btu/h) | 11,500 | 12,000 |
Where a measurement is missing
A dash in the comparison means we could not confirm that measurement for the pair under the stated conditions. Cooling modulation requires a minimum capacity at 95°F. Indoor cooling noise requires a reading taken in cooling mode. A manufacturer’s general capacity range or an unspecified sound reading goes in its own context.
The cold-climate designation comes from the matching EPA entry when available. Separately, we calculate the percentage of heat retained. ENERGY STAR also considers efficiency and performance verification, so a high percentage alone cannot establish certification.