Mitsubishi Electric GX Premier 12,000 Btu/h class

This single-zone wall system is rated for 12,000 Btu/h of cooling at 95°F outdoors. It uses a 208/230 V supply and R-454B refrigerant.

Indoor unit
MSZ-GX12NL
Outdoor unit
MUZ-GX12NL

Cost and room performance

Equipment and ten years of electricity

$5,061.53

Listed equipment price
$2,676.16 3 retailers
Ten years of electricity
$2,385.37
Annual electricity use
1,325.2 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year

Use the electricity rate from your bill. Enter the heat your room needs each year and the heat it needs removed in summer. A load estimate can supply those figures. The starting values are a shared example.

The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.

Electricity per million Btu

Cooling
39.1 kWh
Heating · Region IV rating
93.5 kWh

Compare models doing the same amount of heating or cooling. A lower number uses less electricity.

What your equipment budget buys at 5°F

Equipment price per 1,000 Btu/h at 5°F
$264.97
Heat available at 5°F
10,100 Btu/h
COP at 5°F
1.8
Electricity per million Btu at 5°F
162.8 kWh

EPA model-family record. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.

How low can the compressor run?

Minimum heating output at 47°F
1,500 Btu/h
Minimum cooling output at 95°F
1,300 Btu/h

Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.

Indoor sound across fan speeds

Cooling sound range
19–45 dB(A)

The range runs from the quietest to the highest published indoor fan setting in cooling mode. Compare fan settings for a bedroom.

Formulas and ranking rules

Equipment prices by retailer

Average equipment price
$2,676.16
3 retailers · $2,641 to $2,744.50 · Checked

Prices are in U.S. dollars for the indoor and outdoor units, before tax and shipping. Installation is a separate cost.

The median equipment price in the 12,000 Btu/h class is $2,380.16 (9 of 9 systems priced).

Earlier price and efficiency score

Weighted score 98.2. The reference for the 12,000 Btu/h class is 100.

Efficiency-only benchmark 104.4.

Weights and same-size benchmarks

Published specifications

Cooling
Rated output at 95°F12,000 Btu/h
Marketed size class12,000 Btu/h
Minimum output at 95°F1,300 Btu/h
Maximum output at 95°F14,000 Btu/h
Seasonal efficiency (SEER2)25.6 Btu/Wh
Efficiency at the rating point (EER2)13.35 Btu/Wh
Rated power input at 95°F900 W
Moisture removal2.5 US pt/h
Sensible heat factor0.77
Heating
Seasonal efficiency (HSPF2, Region IV)10.7 Btu/Wh
Rated output at 47°F14,400 Btu/h
Minimum output at 47°F1,500 Btu/h
Maximum output at 47°F18,100 Btu/h
Rated output at 17°F9,000 Btu/h
Maximum output at 17°F12,000 Btu/h
Maximum output at 5°F10,100 Btu/h
Maximum output at −5°F7,700 Btu/h
Maximum output at −10°F6,780 Btu/h
COP at 47°F · rated output3.84
COP at 17°F · maximum output2.1
COP at 5°F · maximum output1.8
Power at 47°F · rated output1,100 W
Power at 17°F · rated output1,000 W
Power at 5°F · maximum output1,640 W
Sound levels
Indoor, cooling · quietest setting19 dB(A)
Indoor, cooling · highest published level45 dB(A)
Indoor cooling fan stages · published order19 / 22 / 30 / 37 / 45 dB(A)
Indoor, heating · quietest setting19 dB(A)
Indoor, heating · highest published level43 dB(A)
Indoor heating fan stages · published order19 / 22 / 30 / 37 / 43 dB(A)
Outdoor unit in cooling mode49 dB(A)
Outdoor unit in heating mode51 dB(A)
Installation details
Power supply208/230 V
RefrigerantR-454B
Specified breaker size15 A
Maximum line-set length65 ft
Maximum vertical separation40 ft
Warranty
Standard parts coverage5 years
Standard compressor coverage7 years

The linked Mitsubishi Electric residential terms apply to purchases from October 15, 2026. Registration, installer and state rules can affect the term.

Reference calculations against fixed benchmarks

The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas

Seasonal cooling electricity savings29.7%
Cooling input reduction at the EER2 test point10.1%
Seasonal heating electricity savings15.9%
Electricity savings with equal heating and cooling loads20.5%
Heat at 5°F as a share of rated heat at 47°F70.1%
Cooling turndown below rated capacity at 95°F89.2%
Quietest cooling mode below a 30 dB(A) reference11 dB(A)

ENERGY STAR cross-check

The listing covers a model family. ENERGY STAR publishes the outdoor unit as MUZ-GX12NL*** and the indoor unit as MSZ-GX12NL***.

ENERGY STAR ID3893654
AHRI reference216626285
Cold Climate designationYes
Rated cooling12,000 Btu/h
Heating at 47°F14,400 Btu/h
Heating at 17°F9,000 Btu/h
Heating at 5°F10,100 Btu/h
COP at 5°F1.8
SEER225.6 Btu/Wh
EER213.35 Btu/Wh
HSPF210.7 Btu/Wh
5°F output as a share of 47°F rated output70.14%

minisplitscout.com/systems/msz-gx12nl--muz-gx12nl/