ACiQ Platinum Extreme Heat 12,000 Btu/h class

This single-zone wall system is rated for 12,000 Btu/h of cooling at 95°F outdoors. It uses a 208/230 V supply and R-454B refrigerant.

Indoor unit
ACIQ-12W-HH-MD
Outdoor unit
ACIQ-12ZPL-HP230C

Cost and room performance

Equipment and ten years of electricity

$4,072.94

Listed equipment price
$1,649.99 2 retailers
Ten years of electricity
$2,422.95
Annual electricity use
1,346.1 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year

Use the electricity rate from your bill. Enter the heat your room needs each year and the heat it needs removed in summer. A load estimate can supply those figures. The starting values are a shared example.

The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.

Electricity per million Btu

Cooling
39.4 kWh
Heating · Region IV rating
95.2 kWh

Compare models doing the same amount of heating or cooling. A lower number uses less electricity.

What your equipment budget buys at 5°F

Equipment price per 1,000 Btu/h at 5°F
$143.48
Heat available at 5°F
11,500 Btu/h
COP at 5°F
1.8
Electricity per million Btu at 5°F
162.8 kWh

EPA record for this pair. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.

How low can the compressor run?

Minimum heating output at 47°F
3,800 Btu/h
Minimum cooling output at 95°F
3,800 Btu/h

Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.

Indoor sound across fan speeds

Cooling sound range
Unavailable

ACiQ reports indoor sound by fan speed without identifying the operating mode.

Formulas and ranking rules

Equipment prices by retailer

Average equipment price
$1,649.99
2 retailers · Same listed price · Checked

Prices are in U.S. dollars for the indoor and outdoor units, before tax and shipping. Installation is a separate cost.

The median equipment price in the 12,000 Btu/h class is $2,380.16 (9 of 9 systems priced).

Earlier price and efficiency score

Weighted score 119.7. The reference for the 12,000 Btu/h class is 100.

Efficiency-only benchmark 103.3.

Weights and same-size benchmarks

Published specifications

Cooling
Rated output at 95°F12,000 Btu/h
Minimum output at 95°F3,800 Btu/h
Maximum output at 95°F14,600 Btu/h
Seasonal efficiency (SEER2)25.4 Btu/Wh
Efficiency at the rating point (EER2)13.4 Btu/Wh
Heating
Seasonal efficiency (HSPF2, Region IV)10.5 Btu/Wh
Rated output at 47°F12,000 Btu/h
Minimum output at 47°F3,800 Btu/h
Maximum output at 47°F16,000 Btu/h
Rated output at 17°F9,800 Btu/h
Rated output at 5°F11,500 Btu/h
Maximum output at 5°F11,500 Btu/h
COP at 5°F · rated output1.8
Sound levels
Indoor minimum · operating mode unspecified19.5 dB(A)
Indoor maximum · operating mode unspecified47 dB(A)
Outdoor · operating mode unspecified56 dB(A)
Installation details
Power supply208/230 V
RefrigerantR-454B
Minimum circuit ampacity15 A
Maximum overcurrent protection15 A
System product code810175551692
Warranty
Standard parts coverage5 years
Standard compressor coverage7 years
Extended parts coverage · conditions apply7 years
Extended compressor coverage · conditions apply12 years

The extended term applies to the original registrant after a qualifying residential installation is registered within 90 days. See the warranty for the applicable start date.

Reference calculations against fixed benchmarks

The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas

Seasonal cooling electricity savings29.1%
Cooling input reduction at the EER2 test point10.4%
Seasonal heating electricity savings14.3%
Electricity savings with equal heating and cooling loads19.2%
Heat at 5°F as a share of rated heat at 47°F95.8%
Cooling turndown below rated capacity at 95°F68.3%
Quietest cooling mode below a 30 dB(A) referenceInsufficient comparable data

ENERGY STAR cross-check

The ENERGY STAR listing names both units on this sheet.

ENERGY STAR ID3723316
AHRI reference216032335
Cold Climate designationYes
Rated cooling12,000 Btu/h
Heating at 47°F12,000 Btu/h
Heating at 17°F12,000 Btu/h
Heating at 5°F11,500 Btu/h
COP at 5°F1.8
SEER225.4 Btu/Wh
EER213.4 Btu/Wh
HSPF210.5 Btu/Wh
5°F output as a share of 47°F rated output95.83%

Reading the sources

ACiQ lists indoor sound by fan speed without identifying the operating mode. These levels stay separate from the cooling-only comparison.

minisplitscout.com/systems/aciq-12w-hh-md--aciq-12zpl-hp230c/