Panasonic ClimaPure XZ 9,000 Btu/h class
Panasonic lists 8,700 Btu/h of rated cooling for this single-zone wall system. It uses a 208/230 V supply and R-32 refrigerant.
- Indoor unit
- CS-XZ9AKUAW
- Outdoor unit
- CU-XZ9AKUAC
Cost and room performance
Equipment and ten years of electricity
$5,770.71
- Listed equipment price
- $3,616.16 2 retailers
- Ten years of electricity
- $2,154.55
- Annual electricity use
- 1,197.0 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year
The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.
Electricity per million Btu
- Cooling
- 36.4 kWh
- Heating · Region IV rating
- 83.3 kWh
Compare models doing the same amount of heating or cooling. A lower number uses less electricity.
What your equipment budget buys at 5°F
- Equipment price per 1,000 Btu/h at 5°F
- $309.07
- Heat available at 5°F
- 11,700 Btu/h
- COP at 5°F
- 2.31
- Electricity per million Btu at 5°F
- 126.9 kWh
EPA record for this pair. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.
How low can the compressor run?
- Minimum heating output at 47°F
- Unavailable
- Minimum cooling output at 95°F
- Unavailable
Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.
Indoor sound across fan speeds
- Cooling sound range
- 19–42 dB(A)
The range runs from the quietest to the highest published indoor fan setting in cooling mode. Compare fan settings for a bedroom.
Equipment prices by retailer
- Average equipment price
- $3,616.16
- 2 retailers · $3,425.84 to $3,806.48 · Checked
Prices are in U.S. dollars for the indoor and outdoor units, before tax and shipping. Installation is a separate cost.
- $3,425.84
- $3,806.48
The median equipment price in the 9,000 Btu/h class is $2,336.01 (16 of 16 systems priced).
Earlier price and efficiency score
Weighted score 91.2. The reference for the 9,000 Btu/h class is 100.
Efficiency-only benchmark 109.
Published specifications
Cooling
| Rated cooling capacity | 8,700 Btu/h |
|---|---|
| Published minimum · outdoor temperature unspecified | 2,900 Btu/h |
| Published maximum · outdoor temperature unspecified | 12,600 Btu/h |
| Seasonal efficiency (SEER2) | 27.5 Btu/Wh |
| Efficiency at the rating point (EER2) | 16.4 Btu/Wh |
| Lower published outdoor operating limit | 0 °F |
| Upper published outdoor operating limit | 114.8 °F |
Heating
| Seasonal efficiency (HSPF2, Region IV) | 12 Btu/Wh |
|---|---|
| Nominal output · outdoor temperature unspecified | 10,900 Btu/h |
| Rated output at 17°F | 14,500 Btu/h |
| Maximum output at 5°F | 11,700 Btu/h |
| Published minimum · outdoor temperature unspecified | 3,200 Btu/h |
| Published maximum · outdoor temperature unspecified | 19,900 Btu/h |
| Lower published outdoor operating limit | -15 °F |
| Upper published outdoor operating limit | 75.2 °F |
Sound levels
| Indoor, cooling · quietest setting | 19 dB(A) |
|---|---|
| Indoor, cooling · low fan | 25 dB(A) |
| Indoor, cooling · highest published level | 42 dB(A) |
| Indoor cooling fan stages · published order | 42 / 25 / 19 dB(A) |
| Outdoor unit in cooling mode | 47 dB(A) |
Installation details
| Power supply | 208–230 V / 1 Ph / 60 Hz |
|---|---|
| Refrigerant | R-32 |
Warranty
| Standard parts coverage | 5 years |
|---|---|
| Standard compressor coverage | 7 years |
A qualifying Gold Star installation can extend coverage to 12 years. Consult the program terms for the installation on your quote.
Reference calculations against fixed benchmarks
The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas
| Seasonal cooling electricity savings | 34.5% |
|---|---|
| Cooling input reduction at the EER2 test point | 26.8% |
| Seasonal heating electricity savings | 25.0% |
| Electricity savings with equal heating and cooling loads | 28.2% |
| Heat at 5°F as a share of rated heat at 47°F | 134.5% |
| Cooling turndown below rated capacity at 95°F | Insufficient comparable data |
| Quietest cooling mode below a 30 dB(A) reference | 11 dB(A) |
ENERGY STAR cross-check
The ENERGY STAR listing names both units on this sheet.
| ENERGY STAR ID | 4437549 |
|---|---|
| AHRI reference | 214837752 |
| Cold Climate designation | Yes |
| Rated cooling | 8,700 Btu/h |
| Heating at 47°F | 8,700 Btu/h |
| Heating at 17°F | 14,500 Btu/h |
| Heating at 5°F | 11,700 Btu/h |
| COP at 5°F | 2.31 |
| SEER2 | 27.5 Btu/Wh |
| EER2 | 16.4 Btu/Wh |
| HSPF2 | 12 Btu/Wh |
| 5°F output as a share of 47°F rated output | 134.48% |
Reading the sources