Panasonic EXTERIOS Z 12,000 Btu/h class

Panasonic lists 12,000 Btu/h of rated cooling for this single-zone wall system. It uses a 208/230 V supply and R-32 refrigerant.

Indoor unit
CS-Z12AKUAW
Outdoor unit
CU-XZ12AKUAC

Cost and room performance

Equipment and ten years of electricity

$5,746.05

Listed equipment price
$3,487.59 single retailer
Ten years of electricity
$2,258.46
Annual electricity use
1,254.7 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year

Use the electricity rate from your bill. Enter the heat your room needs each year and the heat it needs removed in summer. A load estimate can supply those figures. The starting values are a shared example.

The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.

Electricity per million Btu

Cooling
40 kWh
Heating · Region IV rating
85.5 kWh

Compare models doing the same amount of heating or cooling. A lower number uses less electricity.

What your equipment budget buys at 5°F

Equipment price per 1,000 Btu/h at 5°F
$254.57
Heat available at 5°F
13,700 Btu/h
COP at 5°F
2.11
Electricity per million Btu at 5°F
138.9 kWh

EPA record for this pair. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.

How low can the compressor run?

Minimum heating output at 47°F
Unavailable
Minimum cooling output at 95°F
Unavailable

Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.

Indoor sound across fan speeds

Cooling sound range
19–44 dB(A)

The range runs from the quietest to the highest published indoor fan setting in cooling mode. Compare fan settings for a bedroom.

Formulas and ranking rules

Equipment prices by retailer

Single retailer price
$3,487.59
1 retailer · Checked

Prices are in U.S. dollars for the indoor and outdoor units, before tax and shipping. Installation is a separate cost.

The median equipment price in the 12,000 Btu/h class is $2,380.16 (9 of 9 systems priced).

Earlier price and efficiency score

Weighted score 93. Provisional · Based on one retailer. The reference for the 12,000 Btu/h class is 100.

Efficiency-only benchmark 109.5.

Weights and same-size benchmarks

Published specifications

Cooling
Rated cooling capacity12,000 Btu/h
Published minimum · outdoor temperature unspecified2,900 Btu/h
Published maximum · outdoor temperature unspecified16,100 Btu/h
Seasonal efficiency (SEER2)25 Btu/Wh
Efficiency at the rating point (EER2)15 Btu/Wh
Lower published outdoor operating limit0 °F
Upper published outdoor operating limit114.8 °F
Heating
Seasonal efficiency (HSPF2, Region IV)11.7 Btu/Wh
Nominal output · outdoor temperature unspecified12,000 Btu/h
Rated output at 17°F16,500 Btu/h
Maximum output at 5°F13,700 Btu/h
Published minimum · outdoor temperature unspecified3,200 Btu/h
Published maximum · outdoor temperature unspecified23,600 Btu/h
Lower published outdoor operating limit-15 °F
Upper published outdoor operating limit75.2 °F
Sound levels
Indoor, cooling · quietest setting19 dB(A)
Indoor, cooling · low fan28 dB(A)
Indoor, cooling · highest published level44 dB(A)
Indoor cooling fan stages · published order44 / 28 / 19 dB(A)
Outdoor unit in cooling mode48 dB(A)
Installation details
Power supply208–230 V / 1 Ph / 60 Hz
RefrigerantR-32
Warranty
Standard parts coverage5 years
Standard compressor coverage7 years

A qualifying Gold Star installation can extend coverage to 12 years. Consult the program terms for the installation on your quote.

Reference calculations against fixed benchmarks

The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas

Seasonal cooling electricity savings28.0%
Cooling input reduction at the EER2 test point20.0%
Seasonal heating electricity savings23.1%
Electricity savings with equal heating and cooling loads24.7%
Heat at 5°F as a share of rated heat at 47°F119.1%
Cooling turndown below rated capacity at 95°FInsufficient comparable data
Quietest cooling mode below a 30 dB(A) reference11 dB(A)

ENERGY STAR cross-check

The ENERGY STAR listing names both units on this sheet.

ENERGY STAR ID4437555
AHRI reference215387072
Cold Climate designationYes
Rated cooling12,000 Btu/h
Heating at 47°F11,500 Btu/h
Heating at 17°F16,500 Btu/h
Heating at 5°F13,700 Btu/h
COP at 5°F2.11
SEER225 Btu/Wh
EER215 Btu/Wh
HSPF211.7 Btu/Wh
5°F output as a share of 47°F rated output119.13%

Reading the sources

Panasonic labels its fan settings High, Low and Quiet-Low. The lowest number uses Quiet-Low. The nominal heating figure in the submittal has no stated outdoor temperature.

The Z12 system submittal gives an EER2 of 15.00. An earlier Panasonic model listing showed 14.35. We use the rating from the matched-pair submittal.

minisplitscout.com/systems/cs-z12akuaw--cu-xz12akuac/