GREE Envo R32 18,000 Btu/h class

This single-zone wall system is rated for 18,000 Btu/h of cooling at 95°F outdoors. It uses a 208/230 V supply and R-32 refrigerant.

Indoor unit
ENV18HP230V1R32AH
Outdoor unit
ENV18HP230V1R32AO

Cost and room performance

Equipment and ten years of electricity

$6,369.69

Listed equipment price
$3,635 single retailer
Ten years of electricity
$2,734.69
Annual electricity use
1,519.3 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year

Use the electricity rate from your bill. Enter the heat your room needs each year and the heat it needs removed in summer. A load estimate can supply those figures. The starting values are a shared example.

The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.

Electricity per million Btu

Cooling
40.8 kWh
Heating · Region IV rating
111.1 kWh

Compare models doing the same amount of heating or cooling. A lower number uses less electricity.

What your equipment budget buys at 5°F

Equipment price per 1,000 Btu/h at 5°F
$248.97
Heat available at 5°F
14,600 Btu/h
COP at 5°F
1.9
Electricity per million Btu at 5°F
154.2 kWh

EPA record for this pair. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.

How low can the compressor run?

Minimum heating output at 47°F
Unavailable
Minimum cooling output at 95°F
Unavailable

Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.

Indoor sound across fan speeds

Cooling sound range
29–48 dB(A)

The range runs from the quietest to the highest published indoor fan setting in cooling mode. Compare fan settings for a bedroom.

Formulas and ranking rules

Equipment prices by retailer

Single retailer price
$3,635
1 retailer · Checked

Prices are in U.S. dollars for the indoor and outdoor units, before tax and shipping. Installation is a separate cost.

The median equipment price in the 18,000 Btu/h class is $3,543.50 (13 of 13 systems priced).

Earlier price and efficiency score

Weighted score 100.6. Provisional · Based on one retailer. The reference for the 18,000 Btu/h class is 100.

Efficiency-only benchmark 102.6.

Weights and same-size benchmarks

Published specifications

Cooling
Rated output at 95°F18,000 Btu/h
Published minimum · outdoor temperature unspecified5,118 Btu/h
Published maximum · outdoor temperature unspecified22,178 Btu/h
Seasonal efficiency (SEER2)24.5 Btu/Wh
Efficiency at the rating point (EER2)13.65 Btu/Wh
Moisture removal3.8 US pt/h
Lower published outdoor operating limit-20 °F
Upper published outdoor operating limit122 °F
Heating
Seasonal efficiency (HSPF2, Region IV)9 Btu/Wh
Rated output at 47°F18,000 Btu/h
Maximum output at 47°F22,511 Btu/h
Rated output at 17°F14,700 Btu/h
Maximum output at 17°F17,363 Btu/h
Rated output at 5°F14,600 Btu/h
Maximum output at 5°F15,010 Btu/h
Published minimum · outdoor temperature unspecified4,436 Btu/h
Published maximum · outdoor temperature unspecified22,178 Btu/h
COP at 5°F · rated output1.9
COP at 5°F · maximum output2.04
Power at 5°F · maximum output2,152 W
Lower published outdoor operating limit-22 °F
Upper published outdoor operating limit86 °F
Sound levels
Indoor, cooling · quietest setting29 dB(A)
Indoor, cooling · highest published level48 dB(A)
Indoor cooling fan stages · published order48 / 43 / 41 / 39 / 37 / 33 / 29 dB(A)
Outdoor · operating mode unspecified59 dB(A)
Installation details
Power supply208–230 V / 1 Ph / 60 Hz
RefrigerantR-32
Minimum circuit ampacity16 A
Maximum overcurrent protection20 A
Maximum line-set length131 ft
Maximum vertical separation82 ft
Warranty
Standard parts coverage5 years
Standard compressor coverage7 years

A qualifying GREE Select installation and registration can extend coverage to 10 years. The linked warranty program lists the conditions.

Reference calculations against fixed benchmarks

The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas

Seasonal cooling electricity savings26.5%
Cooling input reduction at the EER2 test point12.1%
Seasonal heating electricity savings0.0%
Electricity savings with equal heating and cooling loads8.8%
Heat at 5°F as a share of rated heat at 47°F81.1%
Cooling turndown below rated capacity at 95°FInsufficient comparable data
Quietest cooling mode below a 30 dB(A) reference1 dB(A)

ENERGY STAR cross-check

The ENERGY STAR listing names both units on this sheet.

ENERGY STAR ID3542773
AHRI reference214777850
Cold Climate designationYes
Rated cooling18,000 Btu/h
Heating at 47°F18,000 Btu/h
Heating at 17°F14,700 Btu/h
Heating at 5°F14,600 Btu/h
COP at 5°F1.9
SEER224.5 Btu/Wh
EER213.65 Btu/Wh
HSPF29 Btu/Wh
5°F output as a share of 47°F rated output81.11%

Reading the sources

GREE’s extended heating tables use full output with a 70°F indoor dry-bulb temperature. The system submittal reports rated output separately.