Daikin ENTRA 9,000 Btu/h class

This single-zone wall system is rated for 9,000 Btu/h of cooling at 95°F outdoors. It uses a 208/230 V supply and R-32 refrigerant.

Indoor unit
FTXC09BVJU9
Outdoor unit
RXC09BVJU9

Cost and room performance

Equipment and ten years of electricity

$4,327.65

Listed equipment price
$1,210 2 retailers
Ten years of electricity
$3,117.65
Annual electricity use
1,732.0 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year

Use the electricity rate from your bill. Enter the heat your room needs each year and the heat it needs removed in summer. A load estimate can supply those figures. The starting values are a shared example.

The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.

Electricity per million Btu

Cooling
55.6 kWh
Heating · Region IV rating
117.6 kWh

Compare models doing the same amount of heating or cooling. A lower number uses less electricity.

What your equipment budget buys at 5°F

Equipment price per 1,000 Btu/h at 5°F
Unavailable
Heat available at 5°F
Unavailable
COP at 5°F
Unavailable
Electricity per million Btu at 5°F
Unavailable

A matched EPA winter rating is unavailable. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.

How low can the compressor run?

Minimum heating output at 47°F
3,000 Btu/h
Minimum cooling output at 95°F
3,000 Btu/h

Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.

Indoor sound across fan speeds

Cooling sound range
21–43 dB(A)

The range runs from the quietest to the highest published indoor fan setting in cooling mode. Compare fan settings for a bedroom.

Formulas and ranking rules

Equipment prices by retailer

Average equipment price
$1,210
2 retailers · $1,185 to $1,235 · Checked

Prices are in U.S. dollars for the indoor and outdoor units, before tax and shipping. Installation is a separate cost.

The median equipment price in the 9,000 Btu/h class is $2,336.01 (16 of 16 systems priced).

Earlier price and efficiency score

Weighted score 121. The reference for the 9,000 Btu/h class is 100.

Efficiency-only benchmark 72.9.

Weights and same-size benchmarks

Published specifications

Cooling
Rated output at 95°F9,000 Btu/h
Minimum output at 95°F3,000 Btu/h
Maximum output at 95°F10,500 Btu/h
Seasonal efficiency (SEER2)18 Btu/Wh
Efficiency at the rating point (EER2)9.8 Btu/Wh

The cooling test uses 95°F dry-bulb / 75°F wet-bulb outdoors and 80°F dry-bulb / 67°F wet-bulb indoors.

Heating
Seasonal efficiency (HSPF2, Region IV)8.5 Btu/Wh
Rated output at 47°F9,000 Btu/h
Minimum output at 47°F3,000 Btu/h
Maximum output at 47°F11,200 Btu/h
COP at 5°F · rated output1.8
Sound levels
Indoor, cooling · quietest setting21 dB(A)
Indoor, cooling · highest published level43 dB(A)
Indoor, heating · quietest setting25 dB(A)
Indoor, heating · highest published level41 dB(A)
Outdoor unit in cooling mode49 dB(A)
Outdoor unit in heating mode50 dB(A)
Installation details
Power supply208/230 V
RefrigerantR-32
Maximum overcurrent protection15 A
Maximum line-set length65.62 ft
Indoor unit weight18 lb
Outdoor unit weight55 lb
Warranty
Standard parts coverage5 years
Extended parts coverage · conditions apply10 years

Daikin’s extended term requires registration within 60 days for the original owner-occupant, subject to state exceptions. See the coverage certificate for eligibility.

Reference calculations against fixed benchmarks

The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas

Seasonal cooling electricity savings0.0%
Cooling input reduction at the EER2 test point-22.4%
Seasonal heating electricity savings-5.9%
Electricity savings with equal heating and cooling loads-3.9%
Heat at 5°F as a share of rated heat at 47°FInsufficient comparable data
Cooling turndown below rated capacity at 95°F66.7%
Quietest cooling mode below a 30 dB(A) reference9 dB(A)