Daikin AURORA Wall-Mount 12,000 Btu/h class

This single-zone wall system is rated for 10,600 Btu/h of cooling at 95°F outdoors. It uses a 208/230 V supply and R-32 refrigerant.

Indoor unit
FTXV12AVJU9
Outdoor unit
RXT12AVJU9

Cost and room performance

Equipment and ten years of electricity

$5,131.71

Listed equipment price
$2,467 2 retailers
Ten years of electricity
$2,664.71
Annual electricity use
1,480.4 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year

Use the electricity rate from your bill. Enter the heat your room needs each year and the heat it needs removed in summer. A load estimate can supply those figures. The starting values are a shared example.

The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.

Electricity per million Btu

Cooling
50 kWh
Heating · Region IV rating
98 kWh

Compare models doing the same amount of heating or cooling. A lower number uses less electricity.

What your equipment budget buys at 5°F

Equipment price per 1,000 Btu/h at 5°F
$182.74
Heat available at 5°F
13,500 Btu/h
COP at 5°F
1.8
Electricity per million Btu at 5°F
162.8 kWh

EPA model-family record. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.

How low can the compressor run?

Minimum heating output at 47°F
4,400 Btu/h
Minimum cooling output at 95°F
4,400 Btu/h

Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.

Indoor sound across fan speeds

Cooling sound range
19–45 dB(A)

The range runs from the quietest to the highest published indoor fan setting in cooling mode. Compare fan settings for a bedroom.

Formulas and ranking rules

Equipment prices by retailer

Average equipment price
$2,467
2 retailers · $2,376 to $2,558 · Checked

Prices are in U.S. dollars for the indoor and outdoor units, before tax and shipping. Installation is a separate cost.

The median equipment price in the 12,000 Btu/h class is $2,380.16 (9 of 9 systems priced).

Earlier price and efficiency score

Weighted score 93.2. The reference for the 12,000 Btu/h class is 100.

Efficiency-only benchmark 91.1.

Weights and same-size benchmarks

Published specifications

Cooling
Rated output at 95°F10,600 Btu/h
Minimum output at 95°F4,400 Btu/h
Maximum output at 95°F14,600 Btu/h
Seasonal efficiency (SEER2)20 Btu/Wh
Efficiency at the rating point (EER2)12 Btu/Wh

The cooling test uses 95°F dry-bulb / 75°F wet-bulb outdoors and 80°F dry-bulb / 67°F wet-bulb indoors.

Heating
Seasonal efficiency (HSPF2, Region IV)10.2 Btu/Wh
Rated output at 47°F13,500 Btu/h
Minimum output at 47°F4,400 Btu/h
Maximum output at 47°F18,800 Btu/h
Output at 5°F · load unspecified13,500 Btu/h
COP at 5°F · rated output1.8
Sound levels
Indoor, cooling · quietest setting19 dB(A)
Indoor, cooling · highest published level45 dB(A)
Indoor, heating · quietest setting26 dB(A)
Indoor, heating · highest published level45 dB(A)
Outdoor unit in cooling mode50 dB(A)
Outdoor unit in heating mode52 dB(A)
Installation details
Power supply208/230 V
RefrigerantR-32
Maximum overcurrent protection15 A
Maximum line-set length65.62 ft
Indoor unit weight19 lb
Outdoor unit weight73 lb
Warranty
Standard parts coverage5 years
Extended parts coverage · conditions apply12 years

Daikin’s extended term requires registration within 60 days for the original owner-occupant, subject to state exceptions. See the coverage certificate for eligibility.

Reference calculations against fixed benchmarks

The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas

Seasonal cooling electricity savings10.0%
Cooling input reduction at the EER2 test point0.0%
Seasonal heating electricity savings11.8%
Electricity savings with equal heating and cooling loads11.2%
Heat at 5°F as a share of rated heat at 47°F100.0%
Cooling turndown below rated capacity at 95°F58.5%
Quietest cooling mode below a 30 dB(A) reference11 dB(A)

ENERGY STAR cross-check

The listing covers a model family. ENERGY STAR publishes the outdoor unit as RXT12AVJU* and the indoor unit as FTXV12AVJU*.

ENERGY STAR ID3629935
AHRI reference215710688
Cold Climate designationYes
Rated cooling10,600 Btu/h
Heating at 47°F13,500 Btu/h
Heating at 17°F9,500 Btu/h
Heating at 5°F13,500 Btu/h
COP at 5°F1.8
SEER220 Btu/Wh
EER212 Btu/Wh
HSPF210.2 Btu/Wh
5°F output as a share of 47°F rated output100%

Reading the sources

Daikin’s EDUS092401 engineering table and series brochure list 19 dB(A) in the quietest cooling mode. The pair sheet lists 24 dB(A).