GREE Livo R32 9,000 Btu/h class
This single-zone wall system is rated for 9,100 Btu/h of cooling at 95°F outdoors. It uses a 208/230 V supply and R-32 refrigerant.
- Indoor unit
- LIV09HP230V1R32AH
- Outdoor unit
- LIV09HP230V1R32AO
Cost and room performance
Equipment and ten years of electricity
$4,472
- Listed equipment price
- $1,548.50 2 retailers
- Ten years of electricity
- $2,923.50
- Annual electricity use
- 1,624.2 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year
The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.
Electricity per million Btu
- Cooling
- 48.8 kWh
- Heating · Region IV rating
- 113.6 kWh
Compare models doing the same amount of heating or cooling. A lower number uses less electricity.
What your equipment budget buys at 5°F
- Equipment price per 1,000 Btu/h at 5°F
- $203.75
- Heat available at 5°F
- 7,600 Btu/h
- COP at 5°F
- 1.94
- Electricity per million Btu at 5°F
- 151.1 kWh
EPA record for this pair. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.
How low can the compressor run?
- Minimum heating output at 47°F
- Unavailable
- Minimum cooling output at 95°F
- Unavailable
Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.
Indoor sound across fan speeds
- Cooling sound range
- 21–42 dB(A)
The range runs from the quietest to the highest published indoor fan setting in cooling mode. Compare fan settings for a bedroom.
Equipment prices by retailer
- Average equipment price
- $1,548.50
- 2 retailers · $1,267 to $1,830 · Checked
Prices are in U.S. dollars for the indoor and outdoor units, before tax and shipping. Installation is a separate cost.
- SupplyHouseSeller accepts backorders.$1,267
- $1,830
The median equipment price in the 9,000 Btu/h class is $2,336.01 (16 of 16 systems priced).
Earlier price and efficiency score
Weighted score 108.9. The reference for the 9,000 Btu/h class is 100.
Efficiency-only benchmark 81.
Published specifications
Cooling
| Rated output at 95°F | 9,100 Btu/h |
|---|---|
| Published minimum · outdoor temperature unspecified | 2,388 Btu/h |
| Published maximum · outdoor temperature unspecified | 10,300 Btu/h |
| Seasonal efficiency (SEER2) | 20.5 Btu/Wh |
| Efficiency at the rating point (EER2) | 12.5 Btu/Wh |
| Moisture removal | 1.69 US pt/h |
| Lower published outdoor operating limit | 0 °F |
| Upper published outdoor operating limit | 118 °F |
Heating
| Seasonal efficiency (HSPF2, Region IV) | 8.8 Btu/Wh |
|---|---|
| Rated output at 47°F | 10,000 Btu/h |
| Maximum output at 47°F | 13,136 Btu/h |
| Rated output at 17°F | 8,100 Btu/h |
| Maximum output at 17°F | 10,246 Btu/h |
| Rated output at 5°F | 7,600 Btu/h |
| Maximum output at 5°F | 9,327 Btu/h |
| Published minimum · outdoor temperature unspecified | 2,217 Btu/h |
| Published maximum · outdoor temperature unspecified | 13,136 Btu/h |
| COP at 5°F · rated output | 1.94 |
| COP at 5°F · maximum output | 2.47 |
| Power at 5°F · maximum output | 1,106 W |
| Lower published outdoor operating limit | -13 °F |
| Upper published outdoor operating limit | 75 °F |
Sound levels
| Indoor, cooling · quietest setting | 21 dB(A) |
|---|---|
| Indoor, cooling · highest published level | 42 dB(A) |
| Indoor cooling fan stages · published order | 42 / 39 / 37 / 36 / 28 / 25 / 23 / 21 dB(A) |
| Outdoor · operating mode unspecified | 51 dB(A) |
Installation details
| Power supply | 208–230 V / 1 Ph / 60 Hz |
|---|---|
| Refrigerant | R-32 |
| Minimum circuit ampacity | 10 A |
| Maximum overcurrent protection | 15 A |
| Maximum line-set length | 66 ft |
| Maximum vertical separation | 40 ft |
Warranty
| Standard parts coverage | 5 years |
|---|---|
| Standard compressor coverage | 7 years |
A qualifying GREE Select installation and registration can extend coverage to 10 years. The linked warranty program lists the conditions.
Reference calculations against fixed benchmarks
The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas
| Seasonal cooling electricity savings | 12.2% |
|---|---|
| Cooling input reduction at the EER2 test point | 4.0% |
| Seasonal heating electricity savings | -2.3% |
| Electricity savings with equal heating and cooling loads | 2.5% |
| Heat at 5°F as a share of rated heat at 47°F | 76.0% |
| Cooling turndown below rated capacity at 95°F | Insufficient comparable data |
| Quietest cooling mode below a 30 dB(A) reference | 9 dB(A) |
ENERGY STAR cross-check
The ENERGY STAR listing names both units on this sheet.
| ENERGY STAR ID | 4511788 |
|---|---|
| AHRI reference | 214779524 |
| Cold Climate designation | Yes |
| Rated cooling | 9,100 Btu/h |
| Heating at 47°F | 10,000 Btu/h |
| Heating at 17°F | 9,600 Btu/h |
| Heating at 5°F | 7,600 Btu/h |
| COP at 5°F | 1.94 |
| SEER2 | 20.5 Btu/Wh |
| EER2 | 12.5 Btu/Wh |
| HSPF2 | 8.8 Btu/Wh |
| 5°F output as a share of 47°F rated output | 76% |
Reading the sources
GREE’s extended heating tables use full output with a 70°F indoor dry-bulb temperature. The system submittal reports rated output separately.
minisplitscout.com/systems/liv09hp230v1r32ah--liv09hp230v1r32ao/