Mitsubishi Electric WX 12,000 Btu/h class

This single-zone wall system is rated for 12,000 Btu/h of cooling at 95°F outdoors. It uses a 208/230 V supply and R-454B refrigerant.

Indoor unit
MSZ-WX12NL
Outdoor unit
MUZ-WX12NL

Cost and room performance

Equipment and ten years of electricity

$4,849.78

Listed equipment price
$1,732.13 3 retailers
Ten years of electricity
$3,117.65
Annual electricity use
1,732.0 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year

Use the electricity rate from your bill. Enter the heat your room needs each year and the heat it needs removed in summer. A load estimate can supply those figures. The starting values are a shared example.

The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.

Electricity per million Btu

Cooling
55.6 kWh
Heating · Region IV rating
117.6 kWh

Compare models doing the same amount of heating or cooling. A lower number uses less electricity.

What your equipment budget buys at 5°F

Equipment price per 1,000 Btu/h at 5°F
Unavailable
Heat available at 5°F
Unavailable
COP at 5°F
Unavailable
Electricity per million Btu at 5°F
Unavailable

A matched EPA winter rating is unavailable. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.

How low can the compressor run?

Minimum heating output at 47°F
4,500 Btu/h
Minimum cooling output at 95°F
3,800 Btu/h

Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.

Indoor sound across fan speeds

Cooling sound range
22–45 dB(A)

The range runs from the quietest to the highest published indoor fan setting in cooling mode. Compare fan settings for a bedroom.

Formulas and ranking rules

Equipment prices by retailer

Average equipment price
$1,732.13
3 retailers · $1,633.39 to $1,905 · Checked

Prices are in U.S. dollars for the indoor and outdoor units, before tax and shipping. Installation is a separate cost.

The median equipment price in the 12,000 Btu/h class is $2,380.16 (9 of 9 systems priced).

Earlier price and efficiency score

Weighted score 101.1. The reference for the 12,000 Btu/h class is 100.

Efficiency-only benchmark 76.9.

Weights and same-size benchmarks

Published specifications

Cooling
Rated output at 95°F12,000 Btu/h
Marketed size class12,000 Btu/h
Minimum output at 95°F3,800 Btu/h
Maximum output at 95°F12,200 Btu/h
Seasonal efficiency (SEER2)18 Btu/Wh
Efficiency at the rating point (EER2)9 Btu/Wh
Rated power input at 95°F1,330 W
Moisture removal3.1 US pt/h
Sensible heat factor0.71
Heating
Seasonal efficiency (HSPF2, Region IV)8.5 Btu/Wh
Rated output at 47°F12,200 Btu/h
Minimum output at 47°F4,500 Btu/h
Maximum output at 47°F14,500 Btu/h
Rated output at 17°F7,500 Btu/h
Maximum output at 17°F9,000 Btu/h
COP at 47°F · rated output3.28
COP at 17°F · maximum output2.06
Power at 47°F · rated output1,090 W
Power at 17°F · rated output940 W
Sound levels
Indoor, cooling · quietest setting22 dB(A)
Indoor, cooling · highest published level45 dB(A)
Indoor cooling fan stages · published order22 / 30 / 37 / 45 dB(A)
Indoor, heating · quietest setting22 dB(A)
Indoor, heating · highest published level43 dB(A)
Indoor heating fan stages · published order22 / 30 / 37 / 43 dB(A)
Outdoor unit in cooling mode51 dB(A)
Outdoor unit in heating mode51 dB(A)
Installation details
Power supply208/230 V
RefrigerantR-454B
Specified breaker size15 A
Maximum line-set length65 ft
Maximum vertical separation40 ft
Warranty
Standard parts coverage5 years
Standard compressor coverage7 years

The linked Mitsubishi Electric residential terms apply to purchases from June 1, 2026. Registration, installer and state rules can affect the term.

Reference calculations against fixed benchmarks

The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas

Seasonal cooling electricity savings0.0%
Cooling input reduction at the EER2 test point-33.3%
Seasonal heating electricity savings-5.9%
Electricity savings with equal heating and cooling loads-3.9%
Heat at 5°F as a share of rated heat at 47°FInsufficient comparable data
Cooling turndown below rated capacity at 95°F68.3%
Quietest cooling mode below a 30 dB(A) reference8 dB(A)

ENERGY STAR cross-check

We found no matching record in the U.S. heat-pump list we checked on November 23, 2026. The performance figures above come from the linked technical documents.

minisplitscout.com/systems/msz-wx12nl--muz-wx12nl/