GREE Sapphire R32 18,000 Btu/h class

This single-zone wall system is rated for 18,000 Btu/h of cooling at 95°F outdoors. It uses a 208/230 V supply and R-32 refrigerant.

Indoor unit
SAP18HP230V1R32AH
Outdoor unit
SAP18HP230V1R32AO

Cost and room performance

Equipment and ten years of electricity

$6,836.55

Listed equipment price
$4,382 2 retailers
Ten years of electricity
$2,454.55
Annual electricity use
1,363.6 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year

Use the electricity rate from your bill. Enter the heat your room needs each year and the heat it needs removed in summer. A load estimate can supply those figures. The starting values are a shared example.

The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.

Electricity per million Btu

Cooling
36.4 kWh
Heating · Region IV rating
100 kWh

Compare models doing the same amount of heating or cooling. A lower number uses less electricity.

What your equipment budget buys at 5°F

Equipment price per 1,000 Btu/h at 5°F
$243.44
Heat available at 5°F
18,000 Btu/h
COP at 5°F
1.8
Electricity per million Btu at 5°F
162.8 kWh

EPA record for this pair. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.

How low can the compressor run?

Minimum heating output at 47°F
Unavailable
Minimum cooling output at 95°F
Unavailable

Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.

Indoor sound across fan speeds

Cooling sound range
35–49 dB(A)

The range runs from the quietest to the highest published indoor fan setting in cooling mode. Compare fan settings for a bedroom.

Formulas and ranking rules

Equipment prices by retailer

Average equipment price
$4,382
2 retailers · $4,101 to $4,663 · Checked

Prices are in U.S. dollars for the indoor and outdoor units, before tax and shipping. Installation is a separate cost.

The median equipment price in the 18,000 Btu/h class is $3,543.50 (13 of 13 systems priced).

Earlier price and efficiency score

Weighted score 100.4. The reference for the 18,000 Btu/h class is 100.

Efficiency-only benchmark 113.4.

Weights and same-size benchmarks

Published specifications

Cooling
Rated output at 95°F18,000 Btu/h
Published minimum · outdoor temperature unspecified4,435 Btu/h
Published maximum · outdoor temperature unspecified25,590 Btu/h
Seasonal efficiency (SEER2)27.5 Btu/Wh
Efficiency at the rating point (EER2)14.3 Btu/Wh
Moisture removal3.8 US pt/h
Lower published outdoor operating limit-20 °F
Upper published outdoor operating limit122 °F
Heating
Seasonal efficiency (HSPF2, Region IV)10 Btu/Wh
Rated output at 47°F18,600 Btu/h
Maximum output at 47°F26,666 Btu/h
Rated output at 17°F15,500 Btu/h
Maximum output at 17°F19,866 Btu/h
Rated output at 5°F18,000 Btu/h
Maximum output at 5°F18,100 Btu/h
Published minimum · outdoor temperature unspecified5,118 Btu/h
Published maximum · outdoor temperature unspecified26,272 Btu/h
COP at 5°F · rated output1.8
COP at 5°F · maximum output1.76
Power at 5°F · maximum output3,010 W
Lower published outdoor operating limit-22 °F
Upper published outdoor operating limit86 °F
Sound levels
Indoor, cooling · quietest setting35 dB(A)
Indoor, cooling · highest published level49 dB(A)
Indoor cooling fan stages · published order49 / 46 / 45 / 42 / 40 / 38 / 35 dB(A)
Outdoor · operating mode unspecified59 dB(A)
Installation details
Power supply208–230 V / 1 Ph / 60 Hz
RefrigerantR-32
Minimum circuit ampacity23 A
Maximum overcurrent protection25 A
Maximum line-set length131 ft
Maximum vertical separation82 ft
Warranty
Standard parts coverage5 years
Standard compressor coverage7 years

A qualifying GREE Select installation and registration can extend coverage to 10 years. The linked warranty program lists the conditions.

Reference calculations against fixed benchmarks

The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas

Seasonal cooling electricity savings34.5%
Cooling input reduction at the EER2 test point16.1%
Seasonal heating electricity savings10.0%
Electricity savings with equal heating and cooling loads18.2%
Heat at 5°F as a share of rated heat at 47°F96.8%
Cooling turndown below rated capacity at 95°FInsufficient comparable data
Quietest cooling mode below a 30 dB(A) reference-5 dB(A)

ENERGY STAR cross-check

The ENERGY STAR listing names both units on this sheet.

ENERGY STAR ID3555697
AHRI reference215295786
Cold Climate designationYes
Rated cooling18,000 Btu/h
Heating at 47°F18,600 Btu/h
Heating at 17°F19,500 Btu/h
Heating at 5°F18,000 Btu/h
COP at 5°F1.8
SEER227.5 Btu/Wh
EER214.3 Btu/Wh
HSPF210 Btu/Wh
5°F output as a share of 47°F rated output96.77%

Reading the sources

GREE’s extended heating tables use full output with a 70°F indoor dry-bulb temperature. The system submittal reports rated output separately.