ACiQ Platinum Extreme Heat 18,000 Btu/h class
This single-zone wall system is rated for 18,000 Btu/h of cooling at 95°F outdoors. It uses a 208/230 V supply and R-454B refrigerant.
- Indoor unit
- ACIQ-18W-HH-MD
- Outdoor unit
- ACIQ-18ZPL-HP230C
Cost and room performance
Equipment and ten years of electricity
$4,377.48
- Listed equipment price
- $1,899.99 2 retailers
- Ten years of electricity
- $2,477.49
- Annual electricity use
- 1,376.4 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year
The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.
Electricity per million Btu
- Cooling
- 46.7 kWh
- Heating · Region IV rating
- 90.9 kWh
Compare models doing the same amount of heating or cooling. A lower number uses less electricity.
What your equipment budget buys at 5°F
- Equipment price per 1,000 Btu/h at 5°F
- $105.56
- Heat available at 5°F
- 18,000 Btu/h
- COP at 5°F
- 1.92
- Electricity per million Btu at 5°F
- 152.6 kWh
EPA record for this pair. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.
How low can the compressor run?
- Minimum heating output at 47°F
- 11,200 Btu/h
- Minimum cooling output at 95°F
- 8,800 Btu/h
Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.
Indoor sound across fan speeds
- Cooling sound range
- Unavailable
ACiQ reports indoor sound by fan speed without identifying the operating mode.
Equipment prices by retailer
- Average equipment price
- $1,899.99
- 2 retailers · Same listed price · Checked
Prices are in U.S. dollars for the indoor and outdoor units, before tax and shipping. Installation is a separate cost.
- $1,899.99
- $1,899.99
The median equipment price in the 18,000 Btu/h class is $3,543.50 (13 of 13 systems priced).
Earlier price and efficiency score
Weighted score 137. The reference for the 18,000 Btu/h class is 100.
Efficiency-only benchmark 104.
Published specifications
Cooling
| Rated output at 95°F | 18,000 Btu/h |
|---|---|
| Minimum output at 95°F | 8,800 Btu/h |
| Maximum output at 95°F | 19,400 Btu/h |
| Seasonal efficiency (SEER2) | 21.4 Btu/Wh |
| Efficiency at the rating point (EER2) | 12.5 Btu/Wh |
Heating
| Seasonal efficiency (HSPF2, Region IV) | 11 Btu/Wh |
|---|---|
| Rated output at 47°F | 18,000 Btu/h |
| Minimum output at 47°F | 11,200 Btu/h |
| Maximum output at 47°F | 19,500 Btu/h |
| Rated output at 17°F | 15,000 Btu/h |
| Rated output at 5°F | 18,000 Btu/h |
| Maximum output at 5°F | 18,000 Btu/h |
| COP at 5°F · rated output | 1.92 |
Sound levels
| Indoor minimum · operating mode unspecified | 19.5 dB(A) |
|---|---|
| Indoor maximum · operating mode unspecified | 49.5 dB(A) |
| Outdoor · operating mode unspecified | 59 dB(A) |
Installation details
| Power supply | 208/230 V |
|---|---|
| Refrigerant | R-454B |
| Minimum circuit ampacity | 19 A |
| Maximum overcurrent protection | 20 A |
| System product code | 810175551708 |
Warranty
| Standard parts coverage | 5 years |
|---|---|
| Standard compressor coverage | 7 years |
| Extended parts coverage · conditions apply | 7 years |
| Extended compressor coverage · conditions apply | 12 years |
The extended term applies to the original registrant after a qualifying residential installation is registered within 90 days. See the warranty for the applicable start date.
Reference calculations against fixed benchmarks
The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas
| Seasonal cooling electricity savings | 15.9% |
|---|---|
| Cooling input reduction at the EER2 test point | 4.0% |
| Seasonal heating electricity savings | 18.2% |
| Electricity savings with equal heating and cooling loads | 17.4% |
| Heat at 5°F as a share of rated heat at 47°F | 100.0% |
| Cooling turndown below rated capacity at 95°F | 51.1% |
| Quietest cooling mode below a 30 dB(A) reference | Insufficient comparable data |
ENERGY STAR cross-check
The ENERGY STAR listing names both units on this sheet.
| ENERGY STAR ID | 3723317 |
|---|---|
| AHRI reference | 216032336 |
| Cold Climate designation | Yes |
| Rated cooling | 18,000 Btu/h |
| Heating at 47°F | 18,000 Btu/h |
| Heating at 17°F | 18,000 Btu/h |
| Heating at 5°F | 18,000 Btu/h |
| COP at 5°F | 1.92 |
| SEER2 | 21.4 Btu/Wh |
| EER2 | 12.5 Btu/Wh |
| HSPF2 | 11 Btu/Wh |
| 5°F output as a share of 47°F rated output | 100% |
Reading the sources
ACiQ lists indoor sound by fan speed without identifying the operating mode. These levels stay separate from the cooling-only comparison.