Daikin OTERRA 230V 9,000 Btu/h class

This single-zone wall system is rated for 9,000 Btu/h of cooling at 95°F outdoors. It uses a 208/230 V supply and R-32 refrigerant.

Indoor unit
FTXF09BVJU9
Outdoor unit
RXF09BVJU9

Cost and room performance

Equipment and ten years of electricity

$4,281.85

Listed equipment price
$1,660 2 retailers
Ten years of electricity
$2,621.85
Annual electricity use
1,456.6 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year

Use the electricity rate from your bill. Enter the heat your room needs each year and the heat it needs removed in summer. A load estimate can supply those figures. The starting values are a shared example.

The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.

Electricity per million Btu

Cooling
47.6 kWh
Heating · Region IV rating
98 kWh

Compare models doing the same amount of heating or cooling. A lower number uses less electricity.

What your equipment budget buys at 5°F

Equipment price per 1,000 Btu/h at 5°F
$215.58
Heat available at 5°F
7,700 Btu/h
COP at 5°F
2
Electricity per million Btu at 5°F
146.5 kWh

EPA model-family record. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.

How low can the compressor run?

Minimum heating output at 47°F
4,400 Btu/h
Minimum cooling output at 95°F
4,400 Btu/h

Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.

Indoor sound across fan speeds

Cooling sound range
19–44 dB(A)

The range runs from the quietest to the highest published indoor fan setting in cooling mode. Compare fan settings for a bedroom.

Formulas and ranking rules

Equipment prices by retailer

Average equipment price
$1,660
2 retailers · $1,566 to $1,754 · Checked

Prices are in U.S. dollars for the indoor and outdoor units, before tax and shipping. Installation is a separate cost.

The median equipment price in the 9,000 Btu/h class is $2,336.01 (16 of 16 systems priced).

Earlier price and efficiency score

Weighted score 108.7. The reference for the 9,000 Btu/h class is 100.

Efficiency-only benchmark 87.3.

Weights and same-size benchmarks

Published specifications

Cooling
Rated output at 95°F9,000 Btu/h
Minimum output at 95°F4,400 Btu/h
Maximum output at 95°F11,200 Btu/h
Seasonal efficiency (SEER2)21 Btu/Wh
Efficiency at the rating point (EER2)12.5 Btu/Wh

The cooling test uses 95°F dry-bulb / 75°F wet-bulb outdoors and 80°F dry-bulb / 67°F wet-bulb indoors.

Heating
Seasonal efficiency (HSPF2, Region IV)10.2 Btu/Wh
Rated output at 47°F10,900 Btu/h
Minimum output at 47°F4,400 Btu/h
Maximum output at 47°F16,000 Btu/h
COP at 5°F · rated output2
Sound levels
Indoor, cooling · quietest setting19 dB(A)
Indoor, cooling · highest published level44 dB(A)
Indoor, heating · quietest setting25 dB(A)
Indoor, heating · highest published level41 dB(A)
Outdoor unit in cooling mode49 dB(A)
Outdoor unit in heating mode50 dB(A)
Installation details
Power supply208/230 V
RefrigerantR-32
Maximum overcurrent protection15 A
Maximum line-set length65.62 ft
Indoor unit weight19 lb
Outdoor unit weight63 lb
Warranty
Standard parts coverage5 years
Extended parts coverage · conditions apply12 years

Daikin’s extended term requires registration within 60 days for the original owner-occupant, subject to state exceptions. See the coverage certificate for eligibility.

Reference calculations against fixed benchmarks

The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas

Seasonal cooling electricity savings14.3%
Cooling input reduction at the EER2 test point4.0%
Seasonal heating electricity savings11.8%
Electricity savings with equal heating and cooling loads12.6%
Heat at 5°F as a share of rated heat at 47°F70.6%
Cooling turndown below rated capacity at 95°F51.1%
Quietest cooling mode below a 30 dB(A) reference11 dB(A)

ENERGY STAR cross-check

The listing covers a model family. ENERGY STAR publishes the outdoor unit as RXF09BVJU* and the indoor unit as FTXF09BVJU*.

ENERGY STAR ID3893643
AHRI reference216620038
Cold Climate designationYes
Rated cooling9,000 Btu/h
Heating at 47°F10,900 Btu/h
Heating at 17°F8,000 Btu/h
Heating at 5°F7,700 Btu/h
COP at 5°F2
SEER221 Btu/Wh
EER212.5 Btu/Wh
HSPF210.2 Btu/Wh
5°F output as a share of 47°F rated output70.64%

Reading the sources

The outdoor cooling sound level is for high fan speed in engineering document EDUS042405. The brochure also lists a 46 dB(A) minimum.