Daikin OTERRA 230V 24,000 Btu/h class
This single-zone wall system is rated for 22,400 Btu/h of cooling at 95°F outdoors. It uses a 208/230 V supply and R-32 refrigerant.
- Indoor unit
- FTXF24BVJU9
- Outdoor unit
- RXF24BVJU9
Cost and room performance
Equipment and ten years of electricity
$5,855.88
- Listed equipment price
- $3,104 2 retailers
- Ten years of electricity
- $2,751.88
- Annual electricity use
- 1,528.8 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year
The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.
Electricity per million Btu
- Cooling
- 47.6 kWh
- Heating · Region IV rating
- 105.3 kWh
Compare models doing the same amount of heating or cooling. A lower number uses less electricity.
What your equipment budget buys at 5°F
- Equipment price per 1,000 Btu/h at 5°F
- $184.76
- Heat available at 5°F
- 16,800 Btu/h
- COP at 5°F
- 1.9
- Electricity per million Btu at 5°F
- 154.2 kWh
EPA model-family record. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.
How low can the compressor run?
- Minimum heating output at 47°F
- 6,200 Btu/h
- Minimum cooling output at 95°F
- 7,000 Btu/h
Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.
Indoor sound across fan speeds
- Cooling sound range
- 34–52 dB(A)
The range runs from the quietest to the highest published indoor fan setting in cooling mode. Compare fan settings for a bedroom.
Equipment prices by retailer
- Average equipment price
- $3,104
- 2 retailers · $2,928 to $3,280 · Checked
Prices are in U.S. dollars for the indoor and outdoor units, before tax and shipping. Installation is a separate cost.
- $2,928
- $3,280
The median equipment price in the 24,000 Btu/h class is $4,095.17 (7 of 7 systems priced).
Earlier price and efficiency score
Weighted score 111.5. The reference for the 24,000 Btu/h class is 100.
Efficiency-only benchmark 97.9.
Published specifications
Cooling
| Rated output at 95°F | 22,400 Btu/h |
|---|---|
| Minimum output at 95°F | 7,000 Btu/h |
| Maximum output at 95°F | 26,400 Btu/h |
| Seasonal efficiency (SEER2) | 21 Btu/Wh |
| Efficiency at the rating point (EER2) | 12 Btu/Wh |
The cooling test uses 95°F dry-bulb / 75°F wet-bulb outdoors and 80°F dry-bulb / 67°F wet-bulb indoors.
Heating
| Seasonal efficiency (HSPF2, Region IV) | 9.5 Btu/Wh |
|---|---|
| Rated output at 47°F | 24,000 Btu/h |
| Minimum output at 47°F | 6,200 Btu/h |
| Maximum output at 47°F | 32,000 Btu/h |
| COP at 5°F · rated output | 1.9 |
Sound levels
| Indoor, cooling · quietest setting | 34 dB(A) |
|---|---|
| Indoor, cooling · highest published level | 52 dB(A) |
| Indoor, heating · quietest setting | 34 dB(A) |
| Indoor, heating · highest published level | 49 dB(A) |
| Outdoor unit in cooling mode | 54 dB(A) |
| Outdoor unit in heating mode | 57 dB(A) |
Installation details
| Power supply | 208/230 V |
|---|---|
| Refrigerant | R-32 |
| Maximum overcurrent protection | 25 A |
| Maximum line-set length | 98.5 ft |
| Indoor unit weight | 28 lb |
| Outdoor unit weight | 113 lb |
Warranty
| Standard parts coverage | 5 years |
|---|---|
| Extended parts coverage · conditions apply | 12 years |
Daikin’s extended term requires registration within 60 days for the original owner-occupant, subject to state exceptions. See the coverage certificate for eligibility.
Reference calculations against fixed benchmarks
The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas
| Seasonal cooling electricity savings | 14.3% |
|---|---|
| Cooling input reduction at the EER2 test point | 0.0% |
| Seasonal heating electricity savings | 5.3% |
| Electricity savings with equal heating and cooling loads | 8.3% |
| Heat at 5°F as a share of rated heat at 47°F | 70.0% |
| Cooling turndown below rated capacity at 95°F | 68.8% |
| Quietest cooling mode below a 30 dB(A) reference | -4 dB(A) |
ENERGY STAR cross-check
The listing covers a model family. ENERGY STAR publishes the outdoor unit as RXF24BVJU* and the indoor unit as FTXF24BVJU*.
| ENERGY STAR ID | 3998711 |
|---|---|
| AHRI reference | 217005315 |
| Cold Climate designation | Yes |
| Rated cooling | 22,400 Btu/h |
| Heating at 47°F | 24,000 Btu/h |
| Heating at 17°F | 16,400 Btu/h |
| Heating at 5°F | 16,800 Btu/h |
| COP at 5°F | 1.9 |
| SEER2 | 21 Btu/Wh |
| EER2 | 12 Btu/Wh |
| HSPF2 | 9.5 Btu/Wh |
| 5°F output as a share of 47°F rated output | 70% |
Reading the sources