Daikin OTERRA 230V 24,000 Btu/h class

This single-zone wall system is rated for 22,400 Btu/h of cooling at 95°F outdoors. It uses a 208/230 V supply and R-32 refrigerant.

Indoor unit
FTXF24BVJU9
Outdoor unit
RXF24BVJU9

Cost and room performance

Equipment and ten years of electricity

$5,855.88

Listed equipment price
$3,104 2 retailers
Ten years of electricity
$2,751.88
Annual electricity use
1,528.8 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year

Use the electricity rate from your bill. Enter the heat your room needs each year and the heat it needs removed in summer. A load estimate can supply those figures. The starting values are a shared example.

The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.

Electricity per million Btu

Cooling
47.6 kWh
Heating · Region IV rating
105.3 kWh

Compare models doing the same amount of heating or cooling. A lower number uses less electricity.

What your equipment budget buys at 5°F

Equipment price per 1,000 Btu/h at 5°F
$184.76
Heat available at 5°F
16,800 Btu/h
COP at 5°F
1.9
Electricity per million Btu at 5°F
154.2 kWh

EPA model-family record. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.

How low can the compressor run?

Minimum heating output at 47°F
6,200 Btu/h
Minimum cooling output at 95°F
7,000 Btu/h

Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.

Indoor sound across fan speeds

Cooling sound range
34–52 dB(A)

The range runs from the quietest to the highest published indoor fan setting in cooling mode. Compare fan settings for a bedroom.

Formulas and ranking rules

Equipment prices by retailer

Average equipment price
$3,104
2 retailers · $2,928 to $3,280 · Checked

Prices are in U.S. dollars for the indoor and outdoor units, before tax and shipping. Installation is a separate cost.

The median equipment price in the 24,000 Btu/h class is $4,095.17 (7 of 7 systems priced).

Earlier price and efficiency score

Weighted score 111.5. The reference for the 24,000 Btu/h class is 100.

Efficiency-only benchmark 97.9.

Weights and same-size benchmarks

Published specifications

Cooling
Rated output at 95°F22,400 Btu/h
Minimum output at 95°F7,000 Btu/h
Maximum output at 95°F26,400 Btu/h
Seasonal efficiency (SEER2)21 Btu/Wh
Efficiency at the rating point (EER2)12 Btu/Wh

The cooling test uses 95°F dry-bulb / 75°F wet-bulb outdoors and 80°F dry-bulb / 67°F wet-bulb indoors.

Heating
Seasonal efficiency (HSPF2, Region IV)9.5 Btu/Wh
Rated output at 47°F24,000 Btu/h
Minimum output at 47°F6,200 Btu/h
Maximum output at 47°F32,000 Btu/h
COP at 5°F · rated output1.9
Sound levels
Indoor, cooling · quietest setting34 dB(A)
Indoor, cooling · highest published level52 dB(A)
Indoor, heating · quietest setting34 dB(A)
Indoor, heating · highest published level49 dB(A)
Outdoor unit in cooling mode54 dB(A)
Outdoor unit in heating mode57 dB(A)
Installation details
Power supply208/230 V
RefrigerantR-32
Maximum overcurrent protection25 A
Maximum line-set length98.5 ft
Indoor unit weight28 lb
Outdoor unit weight113 lb
Warranty
Standard parts coverage5 years
Extended parts coverage · conditions apply12 years

Daikin’s extended term requires registration within 60 days for the original owner-occupant, subject to state exceptions. See the coverage certificate for eligibility.

Reference calculations against fixed benchmarks

The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas

Seasonal cooling electricity savings14.3%
Cooling input reduction at the EER2 test point0.0%
Seasonal heating electricity savings5.3%
Electricity savings with equal heating and cooling loads8.3%
Heat at 5°F as a share of rated heat at 47°F70.0%
Cooling turndown below rated capacity at 95°F68.8%
Quietest cooling mode below a 30 dB(A) reference-4 dB(A)

ENERGY STAR cross-check

The listing covers a model family. ENERGY STAR publishes the outdoor unit as RXF24BVJU* and the indoor unit as FTXF24BVJU*.

ENERGY STAR ID3998711
AHRI reference217005315
Cold Climate designationYes
Rated cooling22,400 Btu/h
Heating at 47°F24,000 Btu/h
Heating at 17°F16,400 Btu/h
Heating at 5°F16,800 Btu/h
COP at 5°F1.9
SEER221 Btu/Wh
EER212 Btu/Wh
HSPF29.5 Btu/Wh
5°F output as a share of 47°F rated output70%

Reading the sources

HSPF2 is 9.5 in engineering document EDUS042405 and the pair sheet. The brochure lists 9.1.

minisplitscout.com/systems/ftxf24bvju9--rxf24bvju9/