Daikin ATMOSPHERA 9,000 Btu/h class
This single-zone wall system is rated for 9,000 Btu/h of cooling at 95°F outdoors. It uses a 208/230 V supply and R-32 refrigerant.
- Indoor unit
- FTXM09WVJU9
- Outdoor unit
- RXM09WVJU9
Cost and room performance
Equipment and ten years of electricity
$4,710.08
- Listed equipment price
- $2,446 2 retailers
- Ten years of electricity
- $2,264.08
- Annual electricity use
- 1,257.8 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year
The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.
Electricity per million Btu
- Cooling
- 36.5 kWh
- Heating · Region IV rating
- 89.3 kWh
Compare models doing the same amount of heating or cooling. A lower number uses less electricity.
What your equipment budget buys at 5°F
- Equipment price per 1,000 Btu/h at 5°F
- Unavailable
- Heat available at 5°F
- Unavailable
- COP at 5°F
- Unavailable
- Electricity per million Btu at 5°F
- Unavailable
A matched EPA winter rating is unavailable. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.
How low can the compressor run?
- Minimum heating output at 47°F
- 4,400 Btu/h
- Minimum cooling output at 95°F
- 4,400 Btu/h
Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.
Indoor sound across fan speeds
- Cooling sound range
- 22–43 dB(A)
The range runs from the quietest to the highest published indoor fan setting in cooling mode. Compare fan settings for a bedroom.
Equipment prices by retailer
- Average equipment price
- $2,446
- 2 retailers · $2,355 to $2,537 · Checked
Prices are in U.S. dollars for the indoor and outdoor units, before tax and shipping. Installation is a separate cost.
- $2,355
- $2,537
The median equipment price in the 9,000 Btu/h class is $2,336.01 (16 of 16 systems priced).
Earlier price and efficiency score
Weighted score 101.5. The reference for the 9,000 Btu/h class is 100.
Efficiency-only benchmark 105.5.
Published specifications
Cooling
| Rated output at 95°F | 9,000 Btu/h |
|---|---|
| Minimum output at 95°F | 4,400 Btu/h |
| Maximum output at 95°F | 12,500 Btu/h |
| Seasonal efficiency (SEER2) | 27.4 Btu/Wh |
| Efficiency at the rating point (EER2) | 16.3 Btu/Wh |
The cooling test uses 95°F dry-bulb / 75°F wet-bulb outdoors and 80°F dry-bulb / 67°F wet-bulb indoors.
Heating
| Seasonal efficiency (HSPF2, Region IV) | 11.2 Btu/Wh |
|---|---|
| Rated output at 47°F | 11,000 Btu/h |
| Minimum output at 47°F | 4,400 Btu/h |
| Maximum output at 47°F | 19,500 Btu/h |
| Maximum output at 5°F | 11,000 Btu/h |
| Maximum output at −13°F | 10,000 Btu/h |
| COP at 5°F · rated output | 2 |
Sound levels
| Indoor, cooling · quietest setting | 22 dB(A) |
|---|---|
| Indoor, cooling · highest published level | 43 dB(A) |
| Indoor, heating · quietest setting | 25 dB(A) |
| Indoor, heating · highest published level | 43 dB(A) |
| Outdoor unit in cooling mode | 47 dB(A) |
| Outdoor unit in heating mode | 49 dB(A) |
Installation details
| Power supply | 208/230 V |
|---|---|
| Refrigerant | R-32 |
| Maximum overcurrent protection | 15 A |
| Maximum line-set length | 82.02 ft |
| Indoor unit weight | 29 lb |
| Outdoor unit weight | 96 lb |
Warranty
| Standard parts coverage | 5 years |
|---|---|
| Extended parts coverage · conditions apply | 12 years |
Daikin’s extended term requires registration within 60 days for the original owner-occupant, subject to state exceptions. See the coverage certificate for eligibility.
Reference calculations against fixed benchmarks
The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas
| Seasonal cooling electricity savings | 34.3% |
|---|---|
| Cooling input reduction at the EER2 test point | 26.4% |
| Seasonal heating electricity savings | 19.6% |
| Electricity savings with equal heating and cooling loads | 24.5% |
| Heat at 5°F as a share of rated heat at 47°F | Insufficient comparable data |
| Cooling turndown below rated capacity at 95°F | 51.1% |
| Quietest cooling mode below a 30 dB(A) reference | 8 dB(A) |
ENERGY STAR cross-check
We found no matching record in the U.S. heat-pump list we checked on November 23, 2026. The performance figures above come from the linked technical documents.