Daikin ATMOSPHERA 18,000 Btu/h class
This single-zone wall system is rated for 18,000 Btu/h of cooling at 95°F outdoors. It uses a 208/230 V supply and R-32 refrigerant.
- Indoor unit
- FTXM18WVJU9
- Outdoor unit
- RXM18WVJU9
Cost and room performance
Equipment and ten years of electricity
$6,958.45
- Listed equipment price
- $4,365.50 2 retailers
- Ten years of electricity
- $2,592.95
- Annual electricity use
- 1,440.5 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year
The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.
Electricity per million Btu
- Cooling
- 44.1 kWh
- Heating · Region IV rating
- 100 kWh
Compare models doing the same amount of heating or cooling. A lower number uses less electricity.
What your equipment budget buys at 5°F
- Equipment price per 1,000 Btu/h at 5°F
- Unavailable
- Heat available at 5°F
- Unavailable
- COP at 5°F
- Unavailable
- Electricity per million Btu at 5°F
- Unavailable
A matched EPA winter rating is unavailable. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.
How low can the compressor run?
- Minimum heating output at 47°F
- 9,000 Btu/h
- Minimum cooling output at 95°F
- 9,000 Btu/h
Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.
Indoor sound across fan speeds
- Cooling sound range
- 33–49 dB(A)
The range runs from the quietest to the highest published indoor fan setting in cooling mode. Compare fan settings for a bedroom.
Equipment prices by retailer
- Average equipment price
- $4,365.50
- 2 retailers · $4,204 to $4,527 · Checked
Prices are in U.S. dollars for the indoor and outdoor units, before tax and shipping. Installation is a separate cost.
- $4,204
- $4,527
The median equipment price in the 18,000 Btu/h class is $3,543.50 (13 of 13 systems priced).
Earlier price and efficiency score
Weighted score 93.7. The reference for the 18,000 Btu/h class is 100.
Efficiency-only benchmark 102.1.
Published specifications
Cooling
| Rated output at 95°F | 18,000 Btu/h |
|---|---|
| Minimum output at 95°F | 9,000 Btu/h |
| Maximum output at 95°F | 22,000 Btu/h |
| Seasonal efficiency (SEER2) | 22.7 Btu/Wh |
| Efficiency at the rating point (EER2) | 12.5 Btu/Wh |
The cooling test uses 95°F dry-bulb / 75°F wet-bulb outdoors and 80°F dry-bulb / 67°F wet-bulb indoors.
Heating
| Seasonal efficiency (HSPF2, Region IV) | 10 Btu/Wh |
|---|---|
| Rated output at 47°F | 21,600 Btu/h |
| Minimum output at 47°F | 9,000 Btu/h |
| Maximum output at 47°F | 30,200 Btu/h |
| Maximum output at 5°F | 21,600 Btu/h |
| Maximum output at −13°F | 16,200 Btu/h |
| COP at 5°F · rated output | 1.8 |
Sound levels
| Indoor, cooling · quietest setting | 33 dB(A) |
|---|---|
| Indoor, cooling · highest published level | 49 dB(A) |
| Indoor, heating · quietest setting | 32 dB(A) |
| Indoor, heating · highest published level | 49 dB(A) |
| Outdoor unit in cooling mode | 54 dB(A) |
| Outdoor unit in heating mode | 55 dB(A) |
Installation details
| Power supply | 208/230 V |
|---|---|
| Refrigerant | R-32 |
| Maximum overcurrent protection | 20 A |
| Maximum line-set length | 98.5 ft |
| Indoor unit weight | 33 lb |
| Outdoor unit weight | 132 lb |
Warranty
| Standard parts coverage | 5 years |
|---|---|
| Extended parts coverage · conditions apply | 12 years |
Daikin’s extended term requires registration within 60 days for the original owner-occupant, subject to state exceptions. See the coverage certificate for eligibility.
Reference calculations against fixed benchmarks
The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas
| Seasonal cooling electricity savings | 20.7% |
|---|---|
| Cooling input reduction at the EER2 test point | 4.0% |
| Seasonal heating electricity savings | 10.0% |
| Electricity savings with equal heating and cooling loads | 13.6% |
| Heat at 5°F as a share of rated heat at 47°F | Insufficient comparable data |
| Cooling turndown below rated capacity at 95°F | 50.0% |
| Quietest cooling mode below a 30 dB(A) reference | -3 dB(A) |
ENERGY STAR cross-check
We found no matching record in the U.S. heat-pump list we checked on November 23, 2026. The performance figures above come from the linked technical documents.