Mitsubishi Electric FX Deluxe Hyper-Heating 6,000 Btu/h class

This single-zone wall system is rated for 6,000 Btu/h of cooling at 95°F outdoors. It uses a 208/230 V supply and R-454B refrigerant.

Indoor unit
MSZ-FX06NL
Outdoor unit
MUZ-FX06NLHZ

Cost and room performance

Equipment and ten years of electricity

$4,379.23

Listed equipment price
$2,480.33 3 retailers
Ten years of electricity
$1,898.90
Annual electricity use
1,054.9 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year

Use the electricity rate from your bill. Enter the heat your room needs each year and the heat it needs removed in summer. A load estimate can supply those figures. The starting values are a shared example.

The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.

Electricity per million Btu

Cooling
28.6 kWh
Heating · Region IV rating
76.9 kWh

Compare models doing the same amount of heating or cooling. A lower number uses less electricity.

What your equipment budget buys at 5°F

Equipment price per 1,000 Btu/h at 5°F
$196.85
Heat available at 5°F
12,600 Btu/h
COP at 5°F
2.38
Electricity per million Btu at 5°F
123.1 kWh

EPA model-family record. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.

How low can the compressor run?

Minimum heating output at 47°F
1,700 Btu/h
Minimum cooling output at 95°F
1,700 Btu/h

Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.

Indoor sound across fan speeds

Cooling sound range
20–40 dB(A)

The range runs from the quietest to the highest published indoor fan setting in cooling mode. Compare fan settings for a bedroom.

Formulas and ranking rules

Equipment prices by retailer

Average equipment price
$2,480.33
3 retailers · $2,456 to $2,493 · Checked

Prices are in U.S. dollars for the indoor and outdoor units, before tax and shipping. Installation is a separate cost.

The median equipment price in the 6,000 Btu/h class is $1,940.17 (2 of 2 systems priced).

Earlier price and efficiency score

Weighted score 94.5. The reference for the 6,000 Btu/h class is 100.

Efficiency-only benchmark 105.3.

Weights and same-size benchmarks

Published specifications

Cooling
Rated output at 95°F6,000 Btu/h
Marketed size class6,000 Btu/h
Minimum output at 95°F1,700 Btu/h
Maximum output at 95°F14,000 Btu/h
Seasonal efficiency (SEER2)35 Btu/Wh
Efficiency at the rating point (EER2)21.45 Btu/Wh
Rated power input at 95°F280 W
Moisture removal0 US pt/h
Sensible heat factor1
Heating
Seasonal efficiency (HSPF2, Region IV)13 Btu/Wh
Rated output at 47°F9,000 Btu/h
Minimum output at 47°F1,700 Btu/h
Maximum output at 47°F20,000 Btu/h
Rated output at 17°F6,000 Btu/h
Maximum output at 17°F14,400 Btu/h
Maximum output at 5°F12,600 Btu/h
Maximum output at −5°F10,500 Btu/h
Maximum output at −10°F9,000 Btu/h
Maximum output at −22°F7,400 Btu/h
COP at 47°F · rated output4.88
COP at 17°F · maximum output2.68
COP at 5°F · maximum output2.38
Power at 47°F · rated output540 W
Power at 17°F · rated output510 W
Power at 5°F · maximum output1,550 W
Sound levels
Indoor, cooling · quietest setting20 dB(A)
Indoor, cooling · highest published level40 dB(A)
Indoor cooling fan stages · published order20 / 23 / 29 / 36 / 40 dB(A)
Indoor, heating · quietest setting20 dB(A)
Indoor, heating · highest published level42 dB(A)
Indoor heating fan stages · published order20 / 24 / 29 / 36 / 42 dB(A)
Outdoor unit in cooling mode47 dB(A)
Outdoor unit in heating mode48 dB(A)
Installation details
Power supply208/230 V
RefrigerantR-454B
Specified breaker size15 A
Maximum line-set length65 ft
Maximum vertical separation40 ft
Warranty
Standard parts coverage5 years
Standard compressor coverage7 years

The linked Mitsubishi Electric residential terms apply to purchases from October 15, 2026. Registration, installer and state rules can affect the term.

Reference calculations against fixed benchmarks

The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas

Seasonal cooling electricity savings48.6%
Cooling input reduction at the EER2 test point44.1%
Seasonal heating electricity savings30.8%
Electricity savings with equal heating and cooling loads36.7%
Heat at 5°F as a share of rated heat at 47°F140.0%
Cooling turndown below rated capacity at 95°F71.7%
Quietest cooling mode below a 30 dB(A) reference10 dB(A)

ENERGY STAR cross-check

The listing covers a model family. ENERGY STAR publishes the outdoor unit as MUZ-FX06NLHZ*** and the indoor unit as MSZ-FX06NL***.

ENERGY STAR ID3629928
AHRI reference215611124
Cold Climate designationYes
Rated cooling6,000 Btu/h
Heating at 47°F9,000 Btu/h
Heating at 17°F6,000 Btu/h
Heating at 5°F12,600 Btu/h
COP at 5°F2.38
SEER235 Btu/Wh
EER221.45 Btu/Wh
HSPF213 Btu/Wh
5°F output as a share of 47°F rated output140%

minisplitscout.com/systems/msz-fx06nl--muz-fx06nlhz/