Mitsubishi Electric FX Deluxe Hyper-Heating 9,000 Btu/h class
This single-zone wall system is rated for 9,000 Btu/h of cooling at 95°F outdoors. It uses a 208/230 V supply and R-454B refrigerant.
- Indoor unit
- MSZ-FX09NL
- Outdoor unit
- MUZ-FX09NLHZ
Cost and room performance
Equipment and ten years of electricity
$4,696.02
- Listed equipment price
- $2,798.83 3 retailers
- Ten years of electricity
- $1,897.19
- Annual electricity use
- 1,054.0 kWh
Electricity assumptions$0.18/kWh · 10 million Btu cooling + 10 heating per year
The estimate covers the equipment and its electricity at a constant rate. Budget separately for installation, backup heat and service.
Electricity per million Btu
- Cooling
- 30.2 kWh
- Heating · Region IV rating
- 75.2 kWh
Compare models doing the same amount of heating or cooling. A lower number uses less electricity.
What your equipment budget buys at 5°F
- Equipment price per 1,000 Btu/h at 5°F
- $190.40
- Heat available at 5°F
- 14,700 Btu/h
- COP at 5°F
- 2.2
- Electricity per million Btu at 5°F
- 133.2 kWh
EPA model-family record. Compare heating output with your room’s heat loss at the same outdoor temperature. COP measures heat delivered per unit of electricity at that temperature.
How low can the compressor run?
- Minimum heating output at 47°F
- 3,100 Btu/h
- Minimum cooling output at 95°F
- 2,500 Btu/h
Below the minimum steady output at that outdoor temperature, the system may cycle on and off to meet a lighter load.
Indoor sound across fan speeds
- Cooling sound range
- 20–44 dB(A)
The range runs from the quietest to the highest published indoor fan setting in cooling mode. Compare fan settings for a bedroom.
Equipment prices by retailer
- Average equipment price
- $2,798.83
- 3 retailers · $2,774 to $2,811.75 · Checked
Prices are in U.S. dollars for the indoor and outdoor units, before tax and shipping. Installation is a separate cost.
- $2,774
- $2,810.75
- $2,811.75
The median equipment price in the 9,000 Btu/h class is $2,336.01 (16 of 16 systems priced).
Earlier price and efficiency score
Weighted score 108.4. The reference for the 9,000 Btu/h class is 100.
Efficiency-only benchmark 125.1.
Published specifications
Cooling
| Rated output at 95°F | 9,000 Btu/h |
|---|---|
| Marketed size class | 9,000 Btu/h |
| Minimum output at 95°F | 2,500 Btu/h |
| Maximum output at 95°F | 15,000 Btu/h |
| Seasonal efficiency (SEER2) | 33.1 Btu/Wh |
| Efficiency at the rating point (EER2) | 18.35 Btu/Wh |
| Rated power input at 95°F | 490 W |
| Moisture removal | 0 US pt/h |
| Sensible heat factor | 1 |
Heating
| Seasonal efficiency (HSPF2, Region IV) | 13.3 Btu/Wh |
|---|---|
| Rated output at 47°F | 12,000 Btu/h |
| Minimum output at 47°F | 3,100 Btu/h |
| Maximum output at 47°F | 21,300 Btu/h |
| Rated output at 17°F | 7,700 Btu/h |
| Maximum output at 17°F | 16,300 Btu/h |
| Maximum output at 5°F | 14,700 Btu/h |
| Maximum output at −5°F | 14,500 Btu/h |
| Maximum output at −10°F | 12,000 Btu/h |
| Maximum output at −22°F | 8,700 Btu/h |
| COP at 47°F · rated output | 4.95 |
| COP at 17°F · maximum output | 2.38 |
| COP at 5°F · maximum output | 2.2 |
| Power at 47°F · rated output | 710 W |
| Power at 17°F · rated output | 650 W |
| Power at 5°F · maximum output | 1,950 W |
Sound levels
| Indoor, cooling · quietest setting | 20 dB(A) |
|---|---|
| Indoor, cooling · highest published level | 44 dB(A) |
| Indoor cooling fan stages · published order | 20 / 23 / 29 / 36 / 44 dB(A) |
| Indoor, heating · quietest setting | 20 dB(A) |
| Indoor, heating · highest published level | 42 dB(A) |
| Indoor heating fan stages · published order | 20 / 24 / 29 / 36 / 42 dB(A) |
| Outdoor unit in cooling mode | 49 dB(A) |
| Outdoor unit in heating mode | 49 dB(A) |
Installation details
| Power supply | 208/230 V |
|---|---|
| Refrigerant | R-454B |
| Specified breaker size | 15 A |
| Maximum line-set length | 65 ft |
| Maximum vertical separation | 40 ft |
Warranty
| Standard parts coverage | 5 years |
|---|---|
| Standard compressor coverage | 7 years |
The linked Mitsubishi Electric residential terms apply to purchases from October 15, 2026. Registration, installer and state rules can affect the term.
Reference calculations against fixed benchmarks
The electricity benchmarks use 18 SEER2, 12 EER2 and 9 HSPF2 at the same useful load. A negative saving means higher modeled consumption. Reference formulas
| Seasonal cooling electricity savings | 45.6% |
|---|---|
| Cooling input reduction at the EER2 test point | 34.6% |
| Seasonal heating electricity savings | 32.3% |
| Electricity savings with equal heating and cooling loads | 36.8% |
| Heat at 5°F as a share of rated heat at 47°F | 122.5% |
| Cooling turndown below rated capacity at 95°F | 72.2% |
| Quietest cooling mode below a 30 dB(A) reference | 10 dB(A) |
ENERGY STAR cross-check
The listing covers a model family. ENERGY STAR publishes the outdoor unit as MUZ-FX09NLHZ*** and the indoor unit as MSZ-FX09NL***.
| ENERGY STAR ID | 3629929 |
|---|---|
| AHRI reference | 215611125 |
| Cold Climate designation | Yes |
| Rated cooling | 9,000 Btu/h |
| Heating at 47°F | 12,000 Btu/h |
| Heating at 17°F | 7,700 Btu/h |
| Heating at 5°F | 14,700 Btu/h |
| COP at 5°F | 2.2 |
| SEER2 | 33.1 Btu/Wh |
| EER2 | 18.35 Btu/Wh |
| HSPF2 | 13.3 Btu/Wh |
| 5°F output as a share of 47°F rated output | 122.5% |